New Technique Speeds nanoMRI Imaging
June 9, 2015 | AIP.orgEstimated reading time: 4 minutes
NanoMRI is a scanning technique that produces nondestructive, high-resolution 3-D images of nanoscale objects, and it promises to become a powerful tool for researchers and companies exploring the shape and function of biological materials such as viruses and cells in much the same way as clinical MRI today enables investigation of whole tissues in the human body.
Producing images with near-atomic resolution, however, is immensely difficult and time-consuming. A single nanoMRI scan can require weeks to complete.
Striving to overcome this limitation, researchers from ETH Zurich in Switzerland developed a parallel measurement technique, which they report in a paper appearing this week on the cover of the journal Applied Physics Letters, from AIP Publishing. Information that normally would be measured sequentially -- one bit after another -- can now be measured at the same time with a single detector.
"As a loose analogy, think of how your eyes register green, red, and blue information at the same time using different receptors -- you're measuring different colors in parallel," said Alexander Eichler, a postdoctoral researcher and teaching assistant in Professor C. Degen's group within the Department of Physics at ETH Zurich.
Parallel measurement is also referred to as "multiplexing." After the scan, the researchers need to be able to distinguish where each bit of information belongs in the final picture. For this reason, "different bits of information are encoded in the detector using different phases," he explained. "The term 'phase' refers to a lag in a periodic signal. The phase can be used to differentiate between periodic signals in a way similar to how color is used to differentiate between light signals in the eye."
Magnetic resonance imaging makes use of the fact that certain atoms -- such as 1H, 13C, or 19F -- have nuclei that act like tiny spinning magnets. When these atoms are brought into a magnetic field, they rotate around the field axis in much the same way a spinning top rotates around its vertical axis when it isn't perfectly balanced.
"This rotation is called 'precession,' and it happens at a very precise frequency, known as the 'Larmor frequency,' which depends on the field strength and type of atom," said Eichler.
In a nonhomogeneous field, atoms at different locations have different Larmor frequencies. The atom's location "can be evaluated from the frequency at which it precesses, and an image of the location of all atoms can be composed," he added. "When you look at a clinical MRI picture, you see bright pixels where the density of atoms -- typically 1H -- is high, and dark pixels where the density is low."
The magnetic strength of a single atom is vanishingly small. "Clinical MRI is only possible because a single 3-D pixel -- a "voxel" -- contains about 1018 atoms," Eichler pointed out. "With nanoMRI, we want to detect voxels with only a thousand atoms or less, meaning that we need a sensitivity at least a quadrillion [10^15, or a million billion] times better."
To achieve this, various strategies have been developed. The research team working with Professor Degen demonstrated phase multiplexing with a particular nanoMRI technique called "magnetic resonance force microscopy" (MRFM), in which the atomic nuclei experience a tiny magnetic force that's transferred to a cantilever acting as a mechanical detector. In response to the magnetic force, the cantilever vibrates and then, in turn, an image can be assembled from the measured vibration.
"Our research overcomes one of the major obstacles toward practical high-resolution nanoMRI, namely the forbidding time scales required for sequential measurements," Eichler said. "It brings us closer to the commercial implementation of nanoMRI."
In other words, the team's work greatly accelerates the speed of nanoMRI measurements. By demonstrating parallel measurements of six data points, they've shown that a normal scan of two weeks can now be compressed to within two days.
"Acceleration is limited by technical issues such as the speed of spin reversal and the stability of phase-sensitive detection," Eichler noted. "But, in principle, phase multiplexing might allow compression rates of ten or more. With commercial applications in mind, this time gain is crucial because it makes a huge difference to a pharmaceutical company if a virus can be characterized within three days rather than a month."
Next, the researchers at ETH Zurich are turning their focus to nanoMRI measurements of biological systems. In particular, they'd "like to demonstrate a spatial resolution of better than 1 nanometer," Eichler said. "Taking into account that the number of atoms in a voxel scales with the cube of the length, this will require an improvement in sensitivity of more than 100 relative to prior work -- the current record resolution is about 5 nanometers."
The preparation of biological objects for low-temperature, high-vacuum measurements is a particular challenge, because an ordinary cell, if transferred into vacuum, will simply burst from the pressure imbalance. "When the cell is cooled below the freezing point of water, the liquid inside it may crystallize and destroy the cell membrane," he added. "We're developing strategies to avoid these issues so that we can transfer cells or viruses into our measurement setup without damaging them."
Suggested Items
Inkjet Solder Mask ‘Has Arrived’
04/10/2024 | Pete Starkey, I-Connect007I was delighted to be invited to attend an interactive webinar entitled “Solder Mask Coating Made Easy with Additive Manufacturing,” hosted by SUSS MicroTec Netherlands in Eindhoven. The webinar was introduced and moderated by André Bodegom, managing director at Adeon Technologies, and the speakers were Mariana Van Dam, senior product manager PCB imaging solutions at AGFA in Belgium; Ashley Steers, sales manager at Electra Polymers in the UK; and Dr. Luca Gautero, product manager at SUSS MicroTec Netherlands.
NetVia Group Acquires Direct Imaging from Mivatek
04/09/2024 | Miva TechnologiesMiva Technologies is pleased to announce NetVia Group, Irving, TX has acquired a new Miva 2400NG Dual Tray Direct Imaging System with 30-micron capabilities for inner, outer and soldermask imaging.
Teledyne to Acquire Adimec
02/13/2024 | TeledyneTeledyne Technologies Incorporated announced that it has entered into an agreement to acquire Adimec Holding B.V. and its subsidiaries.
Real Time with... productronica 2023: MivaTek Global Advances Technology With High-res Imaging System
12/08/2023 | Real Time with...productronicaMivaTek's Brendan Hogan talks about how the company employs Digitally Adaptive Rasterization Technology (DART) in their high-res imaging equipment. He also shares how the blurred line between semiconductors and microelectronics is driving broader application of the imaging process.
Keysight Enables Validation of Arbe 4D Imaging Radar Chipset
11/30/2023 | Keysight Technologies, Inc.Keysight Technologies, Inc. announces that Arbe has selected the E8719A Radar Target Solution (RTS) to test the Arbe 4D imaging radar chipset for automotive applications.